RHH, RHW-2 |
|
Cross-Linked Polyethylene Insulated Copper Conductor. For use as building wire, for the distribution of power in circuits not exceeding 2000V. Rated 90°C in wet or dry locations |
Product Summary |
|
UL Listed XLPE Insulated UL 44, Thermoset-Insulated 2000V Sunlight Resistant RoHS |

|
About Us |
|
Appliance Wire |
|
Authorized AWM Styles |
|
Building Wire |
|
Color Code Charts |
|
Cross-Linked Wire |
|
Cross-Linked AWM Styles |
|
Drums & Easy Boxes |
|
Fixture Wire |
|
Flexible Cord |
|
Irrigation Wire |
|
Line Card |
|
Machine Tool Wire |
|
Non-Insulated Copper Wire |
|
Photo Gallery |
|
Standard Spool & Reels |
|
Tracer & Locating Wire |
|
Tray Cable |
|
Underground Pet Fence Wire |
|
Disclaimer |
|
INDUSTRIAL WIRE AND CABLE CORP |
|
Premier manufacturer of high quality copper wire and cable products. |
|
IWC P/N |
AWG Stranding |
COND. DIA. (inches) |
FIN. O.D. (inches) |
APPROX. FIN. WT. (lbs./M’) |
|
RHW1401-2KV |
14 (SOLID) BC |
.064 |
.185 |
25.5 |
|
RWH1407-2KV |
14 (7/.0242) BC |
.072 |
.191 |
26.2 |
|
RHW1201-2KV |
12 (SOLID) BC |
.081 |
.201 |
34.7 |
|
RWH1207-2KV |
12 (7/.0385) BC |
.092 |
.212 |
36.1 |
|
RWH1007-2KV |
10 (7/.0385) BC |
.115 |
.236 |
50.9 |
|
RWH0807-2KV |
8 (7/.0486) BC |
.146 |
.288 |
77.5 |
|
RHW0607-2KV |
6 (7/.0612 )BC |
.184 |
.324 |
112 |
|
RWH0407-2KV |
4 (7/.0772) BC |
.232 |
.373 |
167 |
|
RHW0207-2KV |
2 (7/.0974) BC |
.292 |
.435 |
250 |
|
RHW0119-2KV |
1 (19/.0664) BC |
.330 |
.515 |
327 |
|
RHW1Ø19-2KV |
1/0 (19/.0745) BC |
.370 |
.553 |
398 |
|
RHW2Ø19-2KV |
2/0 (19/.0837) BC |
.420 |
.600 |
500 |
|
Alternate tinned copper conductor available |
||||
|
|
||||
|
|
|||
|
PROPERTIES |
TYPICAL VALUE |
UNIT |
TEST METHOD |
|
Specific Gravity at 23° C |
1.18 |
|
ASTM D-792 |
|
Mechanical properties: Tensile strength at break Tensile strength at yield Elongation at break |
2350 1800 425 |
psi psi % |
UL 1581
|
|
Mechanical properties: After thermal ageing (7days @ 121° C) Tensile strength at break Elongation at break
After 60 day oil @ 75° C Tensile strength at break Elongation at break
After 30 day @ 23° C Tensile strength at break Elongation at break |
2300 375
1975 325
1825 375 |
psi %
psi %
psi % |
UL 1581
|
|
Weatherometer testing: 300 hr. exposure Tensile strength elongation
720 hr. exposure—SUN RES Tensile strength Elongation |
2475 400
2200 375 |
psi psi
% % |
UL 1581
|
|
Crushing test |
1350 |
lb |
UL 1581 |
|
Insulation Resistance
At 23° C At 90° C After 12 weeks at 90° C |
220,000 2,000 2,600 |
MΩ/1000 ft |
UL 1581 |
|
Oxygen Index |
24.5 |
% Oxygen |
ASTM D2863-00 |